Door Hardware
Newly constructed, unsprinklered buildings require door closers on all doors that open onto a corridor in order to maintain exit corridor fire separation rating. The majority of the wood doors at corridors in the building are not rated. Recommend replacing all corridor doors with rated assemblies and proper hardware.
Door Hardware - Classroom:
Doorstops, if provided, must be automatic type. Remove doorstops from all doors opening onto a corridor.
Doors in Series
The minimum space between two doors in a series shall be 48” plus the width of the door swinging into the space. Reconfigure entrance at 1951 addition.
Barry
Elementary
Parker
Elementary
Junior/Senior
High School
Randall
Elementary
Smith
Elementary
Virgil
Elementary
Kaufman Ctr.
Bus Garage
District
Wide
Grease Trap
Replace outdated grease trap in kitchen with a more modern and effective unit to guard against drain line stoppages.