Exits must remain unobstructed at all times to allow the building to be evacuated in an emergency.
The two stairways of the original building do not have the required landing space at the ground floor. Recommend removing existing hollow metal frames and adding Doors in Corridor C2 to provide required landing space and allow a clearer path of egress.
Corridor Lockers
The wood cubbies located in hallways are a fire hazard and do not meet ADA standards. Recommend replacing these with metal corridor lockers. The corridor width allows for 9"x12" lockers. Price is for 140 lockers. Alternative solution is for cubbies to be placed in classrooms.
Water Softener
Provide an automatic water softening system for the domestic hot water feed and for boiler makeup water to reduce scale formation in heating equipment and piping.
Stair Enclosure Doors
Exits must remain unobstructed at all times to allow the building to be evacuated in an emergency.
The two stairways of the original building do not have the required landing space at the ground floor. Recommend removing existing hollow metal frames and adding Doors in Corridor C2 to provide required landing space and allow a clearer path of egress.